MAIN PAGE arrow PRODUCTS arrow (NONDESTRUCTIVE) CONCRETE - Construction Testing Equipments (LAST TECHNOLOGIES) arrow (J20;CORROSION5) A SIMPLE METHOD for IDENTFIYING AREAS of PROBABLE REBAR CORROSION
PDF
(NONDESTRUCTIVE) CONCRETE - Construction Testing Equipments (LAST TECHNOLOGIES) arrow (J20;CORROSION5) A SIMPLE METHOD for IDENTFIYING AREAS of PROBABLE REBAR CORROSION



(J20;CORROSION5) A SIMPLE METHOD for IDENTFIYING AREAS of PROBABLE REBAR CORROSION





(Made in USA)

(FR-J/C317)    OLASI DONATI KOROZYONUNU TANIMLAMAK İÇİN BASİT ve EKONOMİK YÖNTEMLİ KOROZYON EKİPMANI

---------------------------------------------------------

 CorMap™
Economical rebar corrosion analysis

A simple economical method for identifying areas of probable rebar corrosion.

---------------------------------------------

An economical method for identifying areas of corrosion ASTM C-876.

A high impedance voltmeter is connected between the reinforcing steel and a Cu-CuSO4 reference electrode on the concrete surface where a measurement can be made for the half-cell potential.

This measurement of the probability of corrosion activity. By testing at a fixed distance apart, a grid of half-cell potentials can be developed and areas delineated.

          

   Features & Benefits:

Easy to use.

Detachable electrode extension pieces facilitate measurements in hard to reach locations.

High impedance digital meter is designed for tough field conditions.

Economical.

Conforms to ASTM C-876.

              

Technical
Corrosion, which is an electrochemical process, occurs in concrete when oxygen and moisture are present. The actual corrosion is an exchange of energy within different sections of the uncoated reinforcing steel. The relative energy levels can be determined in relation to a reference electrode with a stable electrochemical potential.

     

By connecting a high impedance voltmeter between the reinforcing steel and a reference electrode placed on the concrete surface, a measurement can be made for the half cell potential at the location of the reference cell. This then is a measurement of the probability of corrosion activity in the steel in the vicinity of the reference cell.

    

The reference cell is copper in copper sulphate solution. By taking half cell potential measurements a fixed dis-tance apart a grid of half cell potentials can be quickly made and thus areas delineated with a high probability of corrosion of the reinforcing steel.

To analyze the results, the measurements made with Cor Map can be plotted on a grid and lines of equipotential contours drawn, highlighting areas of possible corrosion activity.

  

For example the following guide is listed in ASTM

C-876 using a copper/copper sulphate half cell:

  • For readings of –350mV and greater there is a 95% chance of active steel corrosion

  • For readings –200 to –350mV there is a 50% chance of active steel corrosion

  • For readings less than –200mV there is only 5% chance of active steel corrosion

The method is particularly useful for:

  • Bridge Decks

  • Parking Garages

  • Concrete Piers & Docks

  • Substructure

  • Tunnel Lining

  • Foundations

             

Specifications

C-CM-4500

High impedance voltmeter

C-CM-4410

Electrode extension pieces—each 18 inches (41 cm) long

C-CM-4400

Reference electrode including copper sulphate reservoir

C-CM-4210

Container of copper sulphate
(capacity 250 ml)

C-CM-4220

Wetting agent reservoir
(capacity 125 ml)

C-CM-4420

Dispensing sponge

C-CM-4300

Cable reel with 250 ft. (80 meters) cable

C-CM-4000

Complete system

            

-----------------------

Web sayfamızda yer alan cihazlar fikir vermek içindir;
model, şekil ve teknik özelliklerini değiştirme hakkı firmamıza aittir.
( FORE CO. reserves the right to alter specifications to equipments to any time. )

 










Last Updated:
Measuring Cans
Measuring Cans


Shore Hardness Tester
Shore Hardness Tester


Marshall Stability Testing Apparatus (Digital)
Marshall Stability Testing Apparatus (Digital)


Refrigeration Testing Apparatus
Refrigeration Testing Apparatus


Liquid Limit Test Set
Liquid Limit Test Set


Grinder with Ring
Grinder with Ring


Point Loading Tester
Point Loading Tester


Heat-Temperature Conductivity Testing Machine (2.PICTURE)
Heat-Temperature Conductivity Testing Machine (2.PICTURE)


GENERAL MEASURING LAB."STANDART" EQUIPMENTS-3
GENERAL MEASURING LAB.


(J25;MOISTURE1)MICROWAVE METER for RAPID DETERMINATION of MOISTURE IN SAND,FINE and COARSE AGGREGATE
(J25;MOISTURE1)MICROWAVE METER for RAPID DETERMINATION of MOISTURE IN SAND,FINE and COARSE AGGREGATE


Sitede bulunan bilgilerin yazılı izin olmadıkça kopyalanması kesinlikle yasaktır. Design by Ahmet KORKMAZ © 2008