MAIN PAGE arrow PRODUCTS arrow (NONDESTRUCTIVE) CONCRETE - Construction Testing Equipments (LAST TECHNOLOGIES) arrow (J19;CORROSION4)MEASURING SYSTEM for The RATE of CORROSION &amp; OTHER PARAMETERS of REINFORCEMENT BARS
PDF
(NONDESTRUCTIVE) CONCRETE - Construction Testing Equipments (LAST TECHNOLOGIES) arrow (J19;CORROSION4)MEASURING SYSTEM for The RATE of CORROSION &amp; OTHER PARAMETERS of REINFORCEMENT BARS



(J19;CORROSION4)MEASURING SYSTEM for The RATE of CORROSION &amp; OTHER PARAMETERS of REINFORCEMENT BARS





(Made in USA)

(FR-J/C316)     KOROZYONUNUN ORANINI ve DONATI BARLARININ DİĞER PARAMETRELERİNİ SAHADA ÖLÇEN PATENTLİ EŞSİZ BİR KOROZYON SİSTEMİ   

-----------------------------------------------

Gecor 6™
Standard rebar corrosion rate field test

A unique patented field system for measuring the rate of corrosion and other parameters of reinforcement bars.

        ---------------------------------------

Measures the rate of corrosion and other parameters of rebars.
The Gecor 6™ utilizes the polarization resistance technique to establish the corrosion rate.

This is a quantitative measure of the amount of steel oxidizing at the time of measurement. Up to 100 readings can be stored in memory for later uploading to a Personal Computer. Relative humidity, temperature, half-cell potentials and concrete resistivity also can be measured. Weighing only nine pounds, the system is easy to use, portable and menu driven.

               

          Features & Benefits:

The U.S.Strategic Highway Research Program (SHRP) describes the system as “giving the corrosion rate most closely matching the true values.”

The system gives important complementary measurements for the interpretation of corrosion rate results.

The “A” sensor measures the corrosion rate and half cell potential.

The “B” sensor measures concrete resistivity, ambient temperature and relative humidity.

Corrosion rate measurement time is 2-5 minutes and up to 100 readings can be stored in the memory for later downloading to a PC.

Weighing only 9 lbs., the system is easy to use, portable, and menu driven.

    

Rebar Corrosion and its effects
Corrosion of reinforcement concrete affects the safety and durability of concrete structures in the following ways:

  1. The steel cross section is reduced, weakening the structure.

  2. The concrete is cracked due to the volume increase in rust.

  3. The steel to concrete bond is reduced when cracking and spalling are initiated.

Corrosion is worsened where there is low concrete cover over the steel, high relative humidity and increased moisture present.

         

Corrosion Rate
A true measure of the corrosion rate is possible using the polarization resistance technique. It has been well established in the laboratory by Stern and Geary that corrosion current is linearly related to polarization resistance.

Over a period of four years Gecor 6™ was developed by several research organizations. The polarization resistance is measured with a central reference electrode, surrounded by an external counter electrode. A unique guard ring and external electrode system confines the area of the rebar tested. This makes the Gecor 6™ the only field method for determining polarization resistance that is verifiable with proven laboratory techniques.

Gecor 6™ gives the corrosion rate (Icorr) which is a quantitative measurement of the amount of steel turning into oxide at the time of measurement. The current can be converted into metal section loss by Faraday’s Equation.

Corrosion rate values measured by Gecor 6™ give precise information on the risk of corrosion and the following broad criteria have been established:

Icorr <0.2µA/cm2 Passive condition
Icorr 0.2 to 0.5µA/cm2 Low corrosion
Icorr 0.5 to 1.0µA/cm2 Moderate corrosion
Icorr >1µA/cm2 High corrosion rate

Corrosion rate measurements with Gecor 6™ should be taken at strategic locations. Other data such as chloride concentration, carbonation depths or half cell potentials and resistivity that can also be measured with Gecor 6™, should be considered.

Corrosion rates vary during the life of the structure, depending on the variations in concrete moisture content, chloride concentration and temperature. Measurements at different intervals should be carri

                  

Complimentary Measurements
Corrosion potentials can be taken, and interpreted to give a probability of corrosion. However, these half cell potential values do not give precise information on the risk of corrosion. A direct relationship between corrosion rate and corrosion potential has not been established.

Concrete resistivity of the area around the sensor is defined from the formula:

RESISTIVITY = 2 x R x D

Where R is the resistance of a pulse between the sensor electrode and the rebar network.
D is electrode diameter and the sensor.

Concrete resistivity measured by Gecor 6™ is useful in the interpretation of corrosion rate because it is related to the moisture content.

>100 to 200k cm Very low corrosion rate even with high chloride concentration or carbonation.
50-100k cm Low corrosion rate
10-50k cm Moderate to high corrosion rate where steel is active
<10k cm Resistivity is not the controlling parameter of the corrosion rate

Since the rate of oxidation is directly related to the amount of heat energy available, temperature has a direct effect on corrosion rate. Relative humidity decreases with increasing temperature and resistivity increases with increasing temperature.

Relative humidity influences the amount of moisture in the pores of the concrete to sustain the corrosion reaction as well as water run off, dew formation, etc.

       

Meter

Dimensions

12 x 8 x 6.5 inches (30 x 20 x 16cm)

Weight

9 Lbs. (4kg)

Batteries

4 “D” type alkaline (24 hours operation)

Power Consumption

1 Watt

LCD Screen

2 line 16 character display

Memory

up to 100 corrosion rate readings

Accessories

100ft (30m) cable for sensor to meter connection
Verification box
RS-232 interface cable
Software for downloading to PC
Constant for Stern and Geary Equation: 26mV


 

Sensor "A"

Dimensions

7” diameter x .8” (18 x 2cm)

Weight

2 Lbs. (0.9kg)

Components

1 copper/copper sulphate central reference electrode
2 copper/copper sulphate confinement sensor electrodes
3 copper sulphate solution reservoirs
2 concentric stainless steel counter electrodes
1 sponge pad

The meter with “A” sensor will measure and store:

Corrosion rate (Stern & Geary law).
Corrosion potential
Concrete Polarization Resistance
Date, time and location of readin

Sensor "B"

Dimensions

10.2” diameter x 1.4” (26 x 3.5cm)

Weight

0.6 Lbs. (0.3kg)

Components

1 copper/copper sulphate reference electrodes
1 copper sulphate solution reservoir
1 stainless steel counter electrode
1 solid state temperature probe –10°C to 80°C
1 Capacitance relative humidity probe 3 to 95%

The meter with “B” sensor will measure and store:

Concrete resistivity
Relative humidity
Temperature (°C)

Sales Numbers

C-CS-5000

(complete system)

C-CS-5100

Meter (electronic)

C-CS-5200

Sensor A

C-CS-5300

Sensor B

C-082-10799-050

Jar of copper sulfate

C-080-107999-400

Varification box

     

-----------------

Web sayfamızda yer alan cihazlar fikir vermek içindir;
model, şekil ve teknik özelliklerini değiştirme hakkı firmamıza aittir.
( FORE CO. reserves the right to alter specifications to equipments to any time. )

 










Last Updated:
Motorized Hydrolic Sample Extruder Jack
Motorized Hydrolic Sample Extruder Jack


Concrete and Mortar Shrinkage Mold
Concrete and Mortar Shrinkage Mold


GENERAL MEASURING LAB."STANDART" EQUIPMENTS-7
GENERAL MEASURING LAB.


Heat-Temperature Conductivity Testing Machine (2.PICTURE)
Heat-Temperature Conductivity Testing Machine (2.PICTURE)


Hand Checker
Hand Checker


DISTILLERS
DISTILLERS


Spectrophotometers
Spectrophotometers


GENERAL MEASURING LAB."STANDART" EQUIPMENTS-6
GENERAL MEASURING LAB.


Segmental Model Test Tank
Segmental Model Test Tank


Manuel Termometers
Manuel Termometers


Sitede bulunan bilgilerin yazılı izin olmadıkça kopyalanması kesinlikle yasaktır. Design by Ahmet KORKMAZ © 2008