(J27;MOISTURE3) M.METER for MEASURING BORE HOLE HUMIDITY in HARDENED CONCRETE |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
(Made in USA)(FR-J/M324) BİR SONRAKİ YAPI İŞLEMİNE GEÇEBİLMEK İÇİN, ORTAYA KONULAN-SERTLEŞEN YENİ YAPININ "KURULUĞUNUN" YETERLİ OLUP - OLMADIĞINI ORTAYA KOYMADA KULLANILAN NEM ÖLÇME CİHAZI------------------------------------------------------------------Humitest System™ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ensures Structure is dry before starting next construction phase. | |
Uniquely designed system to handle concrete bore hole humidity measurements. | |
Re - usable Probe for improved economics. | |
Rapid Response Time of Probe. | |
High accuracy and Long term Stability of Probe. | |
Conforms to ASTM Standard F-2170 |
The James Instruments Humitest System allows the concrete practitioner to monitor and ensure that a new structure is dry enough to proceed with the next phase of construction. This is especially critical for concrete structures requiring a coating, carpeting or similar floor or covering treatment. Installing such treatments before the concrete is sufficiently dry will typically cause expensive failures in the covering treatment. The only accurate way to ensure that the concrete is sufficiently dry enough to safely avoid expensive re-work is via a bore hole humidity test system, such as the Humitest System™.
The system works by first boring a hole into the concrete and inserting a plastic tube in the hole. The plastic tube is then plugged and the system is set to stabilize and the humidity to reach equilibrium. The probe is then inserted into the plastic tube, left to stabilize for a short period of time, and then a reading is taken.
The sleeve is recommended to give readings at various depths in the concrete. As concrete moisture distribution is typically very uneven it is recommended to take readings at different depths depending on the structures exposure.
Specifications | |
Probe | |
Measurement Range | 0…100% RH |
Accuracy | |
0…90% | +/-2%RH |
90…100% | +/-3%RH |
Long Term Stability | ( 1 Year ) 1%RH |
Response Time | 15 S |
Response Time | 30min |
Temperature Range | -20°C…+60°C |
Sensor Diameter | 12mm |
Cable Length | 0.3m |
Probe Length | 69mm |
Housing Material | ABS Plastic |
Sensor Protection Membrane | Filter |
Bore Hole Diameter | 16mm |
Measurement Depth min. | 30mm |
Meter | |
Calculated Quantities | Dewpoint |
Temperature | Absolute |
Temperature | Wet Bulb |
TemperatureResolution | 0.1%RH / 0.1°C |
Power Supplies | 4 AA Batteries |
Display | 2 line LCD |
Approximate Weight | 300 g. |
--------------------------------------------------------------
Web sayfamızda yer alan cihazlar fikir vermek içindir;
model, şekil ve teknik özelliklerini değiştirme hakkı firmamıza aittir.
( FORE CO. reserves the right to alter specifications to equipments to any time. )